Advanced Search

Show simple item record

dc.contributor.authorÖztürk, Ali
dc.contributor.authorDöşoğlu, Mehmet Kenan
dc.contributor.authorPoyraz, Gökhan
dc.contributor.authorTosun, Salih
dc.contributor.authorErcan, İsmail
dc.date.accessioned2021-09-21T12:12:04Z
dc.date.available2021-09-21T12:12:04Z
dc.date.issued12-15 Ağustos 2014en_US
dc.identifier.citationDosoglu M Kenan. Ozturk Ali, Poyraz Gokhan, Tosun Salih, Ercan Ismail, (12.08.2014 - 15.08.2014), Comparison of Squirrel Cage Induction Generator SCIG and Doubly Fed Induction Generator DFIG Based on Wind Farm Transient Stability Analyses International Conference on Advanced Technology & Sciences (ICAT’14), Antalya, TÜRKİYE.en_US
dc.identifier.urihttps://hdl.handle.net/11552/2010
dc.description.abstractThere are various wind turbines that are connected to power systems. Investigation of transient stability is very important during connection of wind turbines to power systems. In this study, behaviors of Squirrel Cage Induction Generator (SCIG) and Doubly Fed Induction Generator (DFIG) that were connected to IEEE 14 bus power system were examined during the breakers short-term on-off. In the solution of the problems, Power Systems Analysis Toolbox (PSAT) software was used. SCIG and DFIG connected to the IEEE 14 bus power system. Transient stability effects of SCIG and DFIG were compared. In the IEEE 14 bus test system, angular speed of generator, some generator buses voltage changes, angular speed and angle of asynchronous generators. As a result of the study, we were observed that DFIG becomes stable in a shorter time than SCIG during line break. Thanks to DFIG had been seen that the oscillations disappear.en_US
dc.language.isoengen_US
dc.publisherInternational Conference on Advanced Technology & Sciencesen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSCIGen_US
dc.subjectDFIGen_US
dc.subjectWind Farmen_US
dc.subjectTransient Stabilityen_US
dc.subjectGenerator Modelingen_US
dc.titleComparison of Squirrel Cage Induction Generator (SCIG) and Doubly Fed Induction Generator (DFIG) Based on Wind Farm Transient Stability Analysesen_US
dc.typeconferenceObjecten_US
dc.relation.ispartofInternational Conference on Advanced Technology & Sciences (ICAT'14)en_US
dc.departmentFakülteler, Mühendislik Fakültesi, Elektrik Elektronik Mühendisliği Bölümüen_US
dc.authorid0000-0002-3511-330Xen_US
dc.identifier.startpage941en_US
dc.identifier.endpage945en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorPoyraz, Gökhan


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record