Browsing MF_EEM_Bildiri Koleksiyonu by Title
Now showing items 1-15 of 15
-
Comparison of Squirrel Cage Induction Generator (SCIG) and Doubly Fed Induction Generator (DFIG) Based on Wind Farm Transient Stability Analyses
(International Conference on Advanced Technology & Sciences, 12-15 Ağus)There are various wind turbines that are connected to power systems. Investigation of transient stability is very important during connection of wind turbines to power systems. In this study, behaviors of Squirrel Cage ... -
Control of DC link Voltage Unit with Fuzzy Logic Controller in the Wind Farm
(IEEE, 2014)In this study, the analysis of wind farm that has Double Feed Induction Generator (DFIG) with Fuzzy Logic Controller (FLC) in its operation connected to the grid is realized. In wind farm, DC voltage control is modeled ... -
Detaylı Ve Sadeleştirilmiş Svc Modellerinin Gerilim Kararlılığı Üzerindeki Etkileri
(Türk Eğitim Sen, 2019)Güç sistemlerinde gerilim kararsızlığının ana nedenlerinden birisi de çalışma koşulları altındaki reaktif güç limit değerleridir. Güç sistemlerinin sürekli ve geçici durum analizinde reaktif güç limit değerlerini iyileştirme ... -
Determination of Optimal Placement Point for Voltage Stability Using SSSC in Power System
(ICAT, 2019)Voltage Stability is defined as the relationship between the bus voltage and the maximum load parameter value depending on the operating condition of the system. The placement of Flexible Alternating Current Transmission ... -
Effects on Static Voltage Stability of the Nonlinear Load Modelling in Power Systems
(IMCOFE, 2017)One of the most problems arising among energy consumer is effect on static voltage stability of the nonlinear load modeling. In this study, effects of static voltage stability of linear load modeling in 11 bus power system ... -
Farklı Dinamik Derece Modelindeki Senkron Generatörlerin Geçici Durumlarda Rüzgar Santrali Üzerindeki Etkileri
(ISITES, 2015)Yapılan bu çalışmada, IEEE 14 baralı güç sisteminde kullanılan senkron generatörlerin farklı dinamik derece modellemeleri ile geçici kararlılık durumları incelenmiştir. Ayrıca generatör baralarına bağlı olan Çift Beslemeli ... -
Farklı Güç Sistemi Denetleyici Modelleri İle Geçici Durum Analizinin İncelenmesi
(2018)Yapılan bu çalışmada 14 baralı güç sisteminde farklı güç sistemleri kıyıcı tiplerinin geçici durumlardaki analizleri yapılmıştır. Bu benzetim çalışması Güç Sistemleri Analizi Programı (PSAT)’da gerçekleştirilmiştir. 14 ... -
Investigation of Static Voltage Stability and Power Losses of ZIP Load Modeling in Power Systems
(ICAT, 2018)One of the most important problems with energy consumer is effect of static load modeling in power systems. In this study, Effects on static voltage stability and active-reactive power losses of static load modeling in 5 ... -
Investigation of Static Voltage Stability Effects of Tap Changer Transformer in Power Systems
(IATS, 2013)In this study, it is emphasized that the effects of the static voltage stability that have been consisted by tap changer. The voltage-maximum loading parameters values of 3 transformers used in IEEE 14 bus system in different ... -
Investigation of Static Voltage Stability Using Multiple STATCOM in Power Systems
(IMCOFE, 2017)Enhancing the Maximum Loading Parameter (MLP) value in power system is very significant in terms of voltage stability. In this study, the relation between voltage and MLP in IEEE 14 buses system. Static Synchronous Compensator ... -
Optimal Placement of TCSC SSSC and UPFC on Power Systems for Maximum Loading Parameter and Minimum Line Losses
(ICAT, 2014)In this study, effects of Thyristor Controller Series Compensator (TCSC) Static Synchronous Series Compensator (SSSC) and United Power Flow Controller (UPFC) on power systems are investigated. In 65 buses system, effects ... -
SVC’nin farklı çalışma koşullarındaki gerilim kararlılığı üzerindeki etkilerinin incelenmesi
(2020)Güç sistemlerinde bara geriliminin reaktif güce bağlı olarak kontrol edilmesi gerilim kararlılığı açısından çok önemli bir konudur. Bu kontrol için Esnek AC İletim Sistemi (FACTS) cihazlarından Statik Var Kompanzatör (SVC) ... -
Transient Stability Analysis with Different Turbine Governor Models in Power Systems
(IMCOFE, 2017)The correct modeling of the generators is very important for safe and economic operation of the power systems. In this study, transient stability of different turbine governor types in 14 buses power systems was analyzed. ... -
Weibull Distribution and Composite Wind Speed Transient Stability Analysis of Wind Turbine Based on DFIG
(IATS, 30 October)In this study, transient stability analyses in wind speed models of the wind turbine based on Double Fed Induction Generator (DFIG) have been investigated. In wind speed models, weibull distribution and composite wind speed ... -
ZIP Yük Modelinde Maksimum Yüklenme Parametre Değerinin STATCOM ve SVC İle İyileştirilmesi
(BILMES, 2018)Bu çalışmada 11 baralı güç sisteminde sabit empedans, akım ve aktif güç (ZIP) yük modelinin statik gerilim kararlılığında oluşturmuş olduğu etkiler incelenmiştir. Maksimum yüklenme analizi için güç sisteminde Esnek AC ...