Advanced exergy analysis of a trigeneration system with a diesel–gasengine operating in a refrigerator plant building

Yükleniyor...
Küçük Resim

Tarih

Yazarlar

Açıkkalp, Emin
Aras, Haydar
Hepbaşlı, Arif

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this paper, a trigeneration system is analyzed using an advanced exergy analysis. The trigenerationsystem is located in the Eskisehir Industry Estate Zone in Turkey. The exergy efficiency of the system wasfound to be 0.354, while the total exergy destruction rate of the system was 16.695 MW. The purpose ofthis study is to determine the improvement potential of the system. The exergy destruction within thecomponents of the facility is divided into four parts: endogenous, exogenous, avoidable and unavoidableexergy destruction. The components of the trigeneration system have strong relationships with eachother since the endogenous exergy destruction of the components is smaller than the exogenous exergydestruction. The avoidable exergy destruction rates are generally greater than the unavoidable ones.Thus, the trigeneration system possesses a high potential for improvement. This analysis indicates thatfrom a thermodynamic perspective, the turbo air compressor is the most important component in thesystem. Through the advanced exergy analysis, information about the relationships among the systemcomponents as well as the potential for further improvements may be provided in more detail

Açıklama

Anahtar Kelimeler

Exergy Analysis, Advanced Exergetic Analysis, Exergy Destruction, Trigeneration System

Kaynak

Energy and Buildings

WoS Q Değeri

Scopus Q Değeri

Cilt

80

Sayı

Künye

Açıkkalp, E., Aras, H., & Hepbasli, A. (2014). Advanced exergy analysis of a trigeneration system with a diesel–gas engine operating in a refrigerator plant building. Energy and buildings, 80, 268-275.

Onay

İnceleme

Ekleyen

Referans Veren