A modeling and simulation study about CO2 amount with web-based indoor air quality monitoring

dc.authorid0000-0003-2267-2206
dc.authorid0000-0003-0324-9111
dc.contributor.authorYalcin, Nesibe
dc.contributor.authorBalta, Deniz
dc.contributor.authorOzmen, Ahmet
dc.date.accessioned2025-05-20T18:53:36Z
dc.date.issued2018
dc.departmentBilecik Şeyh Edebali Üniversitesi
dc.description.abstractHuman breath causes indoor air quality (IAQ) to get worse in overcrowded places such as schools, hospitals, and offices where people spend most of their time, and it is rarely felt. For a healthy and comfortable living environment, pollutant gases must also be monitored in addition to temperature and humidity control. In this respect, carbon dioxide (CO2) is considered as one of the main indoor air pollutants to determine ventilation requirements. In this study, a mathematical model and simulator software have been developed to predict CO2 concentrations under different indoor conditions and to visualize the predicted results that come from the model. During the study some experiments are conducted to validate the model at a faculty building of Sakarya University. In these experiments, first CO2 concentrations are predicted using the model and then they are measured to validate the model for target classrooms under different indoor conditions depending on the number of students, their physical characteristics, and activities. The study shows that increasing the number of students has considerable impacts on the amount of CO2 produced and it can be used as the minimum value of the outdoor ventilation rate. The modeling and simulator software can be used for analyzing alternative building designs such as different ventilation types, occupant profiles, and numbers and dimensions of windows, doors and rooms in terms of IAQ.
dc.identifier.doi10.3906/elk-1612-57
dc.identifier.endpage+
dc.identifier.issn1300-0632
dc.identifier.issn1303-6203
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85048220303
dc.identifier.scopusqualityQ2
dc.identifier.startpage1390
dc.identifier.urihttps://doi.org/10.3906/elk-1612-57
dc.identifier.urihttps://hdl.handle.net/11552/6940
dc.identifier.volume26
dc.identifier.wosWOS:000434009500022
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWoS
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWoS - Science Citation Index Expanded
dc.language.isoen
dc.publisherTubitak Scientific & Technological Research Council Turkey
dc.relation.ispartofTurkish Journal of Electrical Engineering and Computer Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250518
dc.subjectIndoor air quality
dc.subjectmulticompartment IAQ model
dc.subjectsimulator
dc.subjectsoftware monitoring
dc.subjectCO2 estimation
dc.titleA modeling and simulation study about CO2 amount with web-based indoor air quality monitoring
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
2018 - A modeling and simulation study about CO 2 amount with web-based indoor air quality monitoring.pdf
Boyut:
2.34 MB
Biçim:
Adobe Portable Document Format