Advanced Exergoenvironmental Assessment of a Natural Gas-Fired Electricity Generating Facility

dc.authorid0000-0001-5356-1467
dc.contributor.authorAçıkkalp, Emin
dc.contributor.authorAras, Haydar
dc.contributor.authorHepbaşlı, Arif
dc.date.accessioned2021-12-22T14:01:58Z
dc.date.available2021-12-22T14:01:58Z
dc.date.issued2014en_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine ve İmalat Mühendisliği Bölümü
dc.description.abstractThis paper presents conventional and advanced exergoenvironmental analyses of an electricity genera-tion facility located in the Eskisehir Industry Estate Zone, Turkey. This facility consists of gas turbineand steam cycles, which generate electrical power of approximately 37 MW and 18 MW, respectively.Exergy efficiency of the system is 0.402 and exergy destruction rate of the system is 78.242 MW. Unitexergy cost of electrical power generated by the system is 25.66 $/GJ and total exergoeconomic factorof the system is 0.279. Conventional exergy analysis method was applied to the system first. Next, exergyenvironmental impacts of exergy destruction rate within the facility’s components were divided into fourparts generally, as endogenous, exogenous, avoidable and unavoidable environmental impact of exergydestruction rate. Through this analysis, improvement potential of the environmental impacts of the com-ponents and the overall system and the environmental relations between the components were thendetermined. Finally, exergoenvironmental factor was determined as 0.277 and environmental impactof the electricity was 8.472 (Pts/h). The system has 33% development potential for environmental impactswhile its components have weak relations because of big endogenous parts of environmental impacts(80%). It may be concluded that advanced exergoenvironmental analysis indicated that priority shouldbe given to the GT and CC, while defining the improvement strategies.en_US
dc.identifier.citationAçıkkalp, E., Aras, H., & Hepbasli, A. (2014). Advanced exergoenvironmental assessment of a natural gas-fired electricity generating facility. Energy conversion and management, 81, 112-119.en_US
dc.identifier.doi10.1016/j.enconman.2014.02.011
dc.identifier.endpage119en_US
dc.identifier.issn0196-8904
dc.identifier.issn1879-2227
dc.identifier.scopus2-s2.0-84897787661
dc.identifier.scopusqualityQ1
dc.identifier.startpage112en_US
dc.identifier.urihttps://doi.org/10.1016/j.enconman.2014.02.011
dc.identifier.urihttps://hdl.handle.net/11552/2283
dc.identifier.volume81en_US
dc.identifier.wosWOS:000335618400012
dc.identifier.wosqualityQ1
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWoS
dc.indekslendigikaynakWoS - Science Citation Index Expanded
dc.institutionauthorAçıkkalp, Emin
dc.language.isoen
dc.publisherPergamon-Elsevier Scienceen_US
dc.relation.ispartofEnergy Conversion and Management
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectEnvironmental Assessmenten_US
dc.subjectExergoenvironmental Analysisen_US
dc.subjectAdvanced Exergetic Analysisen_US
dc.subjectAdvanced Exergoenvironmental Analysisen_US
dc.subjectExergy Destruction Rateen_US
dc.subjectElectricity Generation Facilityen_US
dc.titleAdvanced Exergoenvironmental Assessment of a Natural Gas-Fired Electricity Generating Facility
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
1-s2.0-S0196890414001216-main.pdf
Boyut:
551.17 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Yayıncı Kopyası_Makale Dosyası

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: