Removal of copper ions by modified sepiolite samples
| dc.authorid | Eren, Bilge/0000-0001-9775-9360 | |
| dc.contributor.author | Eren, Erdal | |
| dc.contributor.author | Eren, Bilge | |
| dc.date.accessioned | 2025-05-20T18:53:27Z | |
| dc.date.issued | 2010 | |
| dc.department | Bilecik Şeyh Edebali Üniversitesi | |
| dc.description.abstract | This paper presents the adsorption of Cu(II) from aqueous solution by raw sepiolite (RS), manganese oxide-coated sepiolite (MCS), and base activated sepiolite (BAS) samples. Adsorption of Cu(II) by sepiolite samples was investigated as a function of the initial Cu(II) concentration, solution pH, ionic strength, temperature and the presence of an inorganic ligand (Cl(-)). Changes in the surface and structure were characterized by means of XRD, IR and N(2) gas adsorption data. The Langmuir monolayer adsorption capacities of RS, MCS and BAS in 0.1 M KNO(3) solution were calculated to be 5.55, 6.70 and 13.46 mg/g, respectively. Delta G, Delta H and Delta S were determined as -18.94 kJ/mol (at 303 K), 25 kJ/mol and 145 J/mol K, -19.51 kJ/mol (at 303 K), 2 kJ/mol and 71 J/mol K and -20.51 kJ/mol (at 303 K), 31 kJ/mol and 170 J/mol K for RS, MCS, and BAS, respectively. | |
| dc.description.sponsorship | Scientific & Technological Research Council of Turkey (TUBITAK) [108T301] | |
| dc.description.sponsorship | The authors thank the Scientific & Technological Research Council of Turkey (TUBITAK) for the financial support (Project no 108T301). They also thank Assoc. Prof. Dr. Yunus Onal in determining porous structures of sepiolite samples. | |
| dc.identifier.doi | 10.5004/dwt.2010.1186 | |
| dc.identifier.endpage | 122 | |
| dc.identifier.issn | 1944-3994 | |
| dc.identifier.issue | 1-3 | |
| dc.identifier.scopus | 2-s2.0-77958011466 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 114 | |
| dc.identifier.uri | https://doi.org/10.5004/dwt.2010.1186 | |
| dc.identifier.uri | https://hdl.handle.net/11552/6865 | |
| dc.identifier.volume | 20 | |
| dc.identifier.wos | WOS:000281958700014 | |
| dc.identifier.wosquality | Q4 | |
| dc.indekslendigikaynak | WoS | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | WoS - Science Citation Index Expanded | |
| dc.language.iso | en | |
| dc.publisher | Desalination Publ | |
| dc.relation.ispartof | Desalination and Water Treatment | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20250518 | |
| dc.subject | Sepiolite | |
| dc.subject | Adsorption | |
| dc.subject | Thermodynamic | |
| dc.subject | Clay | |
| dc.subject | Copper ions | |
| dc.title | Removal of copper ions by modified sepiolite samples | |
| dc.type | Article |












