Entransy Analysis of Irreversible Heat Pump Using Newton and Dulong-Petit Heat Transfer Laws and Relations with its Performance
| dc.authorid | 0000-0001-5356-1467 | |
| dc.contributor.author | Açıkkalp, Emin | |
| dc.date.accessioned | 2021-12-22T13:14:23Z | |
| dc.date.available | 2021-12-22T13:14:23Z | |
| dc.date.issued | 2014 | en_US |
| dc.department | Fakülteler, Mühendislik Fakültesi, Makine ve İmalat Mühendisliği Bölümü | |
| dc.description.abstract | An irreversible heat pump was investigated via entransy analysis and performance criteria. In theanalyses, two different convective heat transfer laws were applied to the considered system: the Newtonand Dulong–Petit heat transfer laws. The irreversibilities in the system are the result of a finite heat trans-fer rate, a heat leak and internal irreversibilities, including friction, turbulence etc. In this study, a ther-modynamic analysis was performed in detail, and the numerical solutions were used for the conductedanalysis. The maximum entransy dissipation (critical points) ranges from 18436.7 kW K to 18855.3 kW Kaccording toyfor Newton’s law; however, there is no maximum point for the Dulon–Petit law. It can beconcluded from this study that entransy should be used among the basic thermodynamic criteria. | en_US |
| dc.identifier.citation | Açıkkalp, E. (2014). Entransy analysis of irreversible heat pump using Newton and Dulong–Petit heat transfer laws and relations with its performance. Energy conversion and management, 86, 792-800. | en_US |
| dc.identifier.doi | 10.1016/j.enconman.2014.06.029 | |
| dc.identifier.endpage | 800 | en_US |
| dc.identifier.issn | 0196-8904 | |
| dc.identifier.issn | 1879-2227 | |
| dc.identifier.scopus | 2-s2.0-84903935652 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 792 | en_US |
| dc.identifier.uri | https://doi.org/10.1016/j.enconman.2014.06.029 | |
| dc.identifier.uri | https://hdl.handle.net/11552/2276 | |
| dc.identifier.volume | 86 | en_US |
| dc.identifier.wos | WOS:000340976900079 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | WoS | |
| dc.indekslendigikaynak | WoS - Science Citation Index Expanded | |
| dc.institutionauthor | Açıkkalp, Emin | |
| dc.language.iso | en | |
| dc.publisher | Pergamon-Elsevier Science | en_US |
| dc.relation.ispartof | Energy Conversion and Management | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Entransy Analysis | en_US |
| dc.subject | Entransy Dissipation | en_US |
| dc.subject | Entropy Generation | en_US |
| dc.subject | Entransy Efficiency | en_US |
| dc.subject | COP | en_US |
| dc.subject | Exergy Efficiency | en_US |
| dc.subject | Irreversible Heat Pump | en_US |
| dc.title | Entransy Analysis of Irreversible Heat Pump Using Newton and Dulong-Petit Heat Transfer Laws and Relations with its Performance | |
| dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 1-s2.0-S0196890414005548-main.pdf
- Boyut:
- 1.31 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Yayıncı Kopyası_Makale Dosyası
Lisans paketi
1 - 1 / 1
Yükleniyor...
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: