EFFECT OF WAVY FIN USAGE ON THERMAL PERFORMANCE OF HEAT EXCHANGER USED IN COMBI BOILERS

dc.authoridYasar, Halit/0000-0002-1863-5085
dc.authoridDurmaz, Ufuk/0000-0001-5534-8117
dc.authoridAYDIN, Ahmet/0000-0002-8402-2068
dc.contributor.authorYasar, Halit
dc.contributor.authorErol, Gulcan Ozel
dc.contributor.authorDurmaz, Ufuk
dc.contributor.authorAydin, Ahmet
dc.contributor.authorKilic, Serhan
dc.contributor.authorEngin, Tahsin
dc.date.accessioned2025-05-20T18:54:07Z
dc.date.issued2020
dc.departmentBilecik Şeyh Edebali Üniversitesi
dc.description.abstractIn this study, performance of a heat exchanger used in combi boilers was investigated numerically for different fin geometries. Analyses were performed at the boiler operation conditions. A commercial CFD software package, FLUENT, was used for numerical simulations. The 3-D steady-state turbulent flow field analysis was carried out and k-s model was preferred as the turbulence model. In the analysis, it was assumed that the heat transfer phenomenon occurred both by conduction cold convection. Flat fin geometry was taken as a reference for the investigation. Variation of the heat transfer and pressure drop values for the wavy fin were compared with the reference geometry. The wave angle and wave radius were taken as the parameters for the wavy fins. For different fin geometries: the outlet temperature of the combustion gases, the heat transfer to the water; and the pressure drop were calculated and the results were presented. Compared with flat fin, average decrease for the outlet temperature of hot gases was obtained as 4 K and average increase for the heat transfer to the water was calculated as 0.68 W On the other hand, the average pressure drop in the heat exchanger with wavy fins was about 70% higher than the flat fin.
dc.identifier.doi10.2298/TSCI180330189Y
dc.identifier.endpage700
dc.identifier.issn0354-9836
dc.identifier.issn2334-7163
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85057139500
dc.identifier.scopusqualityQ3
dc.identifier.startpage693
dc.identifier.urihttps://doi.org/10.2298/TSCI180330189Y
dc.identifier.urihttps://hdl.handle.net/11552/7210
dc.identifier.volume24
dc.identifier.wosWOS:000522446200003
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWoS
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWoS - Science Citation Index Expanded
dc.language.isoen
dc.publisherVinca Inst Nuclear Sci
dc.relation.ispartofThermal Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250518
dc.subjectheat exchanger
dc.subjectcombi boiler
dc.subjectCFD
dc.subjectwavy fin
dc.titleEFFECT OF WAVY FIN USAGE ON THERMAL PERFORMANCE OF HEAT EXCHANGER USED IN COMBI BOILERS
dc.typeArticle

Dosyalar