Reduced and detailed kinetic models comparison for thermal furnace of sulfur recovery units

dc.contributor.authorAndoglu, Ecem M.
dc.contributor.authorDell’Angelo, Anna
dc.contributor.authorRanzi, Eliseo
dc.contributor.authorKaytakoglu, Suleyman
dc.contributor.authorManenti, Flavio
dc.date.accessioned2025-05-20T18:47:40Z
dc.date.issued2019
dc.departmentBilecik Şeyh Edebali Üniversitesi
dc.description.abstractAcid gas obtained from oil refineries contains large amounts of hydrogen sulfide, which are not allowed as the off-gas or burned to the atmosphere. The waste gas collected during the processes in the refineries contains a high amount of sulfur-bearing compounds, hence it should be sent to the sulfur recovery unit (SRU). Modified Claus process is the most common sulfur recovery process that is used around the world in the hydrocarbon processing industry. The thermal furnace is the most important part because the majority of the reactions occur in this unit. The aim of the current study is to investigate the possibility of using a reduced kinetic scheme in DSMOKE simulation environment. The hydrogen sulfide conversions are 75%, 80% and 86% obtained from plant data, detailed kinetic model and reduced kinetic model, respectively. Reduced kinetic model results agree with both detailed kinetic model results and plant data by 5% and 6% error. Copyright © 2019, AIDIC Servizi S.r.l.
dc.description.sponsorshipScientific and Technological 2214/A
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu
dc.identifier.doi10.3303/CET1974109
dc.identifier.endpage654
dc.identifier.issn2283-9216
dc.identifier.scopus2-s2.0-85067071993
dc.identifier.scopusqualityQ3
dc.identifier.startpage649
dc.identifier.urihttps://doi.org/10.3303/CET1974109
dc.identifier.urihttps://hdl.handle.net/11552/6556
dc.identifier.volume74
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherItalian Association of Chemical Engineering - AIDIC
dc.relation.ispartofChemical Engineering Transactions
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_Scopus_20250518
dc.titleReduced and detailed kinetic models comparison for thermal furnace of sulfur recovery units
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale.pdf
Boyut:
855.7 KB
Biçim:
Adobe Portable Document Format