Electrochemical Monitoring of Biointeraction Between Glyphosate and DNA By Using Disposable Pencil Graphite Electrodes

dc.authorid0000-0002-0599-0993
dc.contributor.authorÇongur, Gülşah
dc.date.accessioned2022-09-06T10:47:53Z
dc.date.available2022-09-06T10:47:53Z
dc.date.issued2021en_US
dc.departmentMeslek Yüksekokulları, Sağlık Hizmetleri Meslek Yüksekokulu, Eczane Hizmetleri Bölümü
dc.departmentRektörlük, Biyoteknoloji Uygulama ve Araştırma Merkezi
dc.departmentBŞEÜ
dc.description"Abstract for Online Oral Presentation of"en_US
dc.description.abstractGlyphosate (GLY) is a worldwide known chemical used to control non-specific vegetation. It is evaluated as “probably carcinogenic to humans” by The International Agency for Research on Cancer. Its cytotoxic effects was investigated on tropical frog larvae, mouse oocytes, plants, humans and animals and it was reported that GLY causes DNA double strand-breaks. Therefore, the use of GLY containing pesticides is controversial in many countries. Herein, biointeraction between GLY and double stranded DNA (dsDNA) was performed and this biointeraction was monitored by using disposable pencil graphite electrodes (PGEs). In this study, as the first step, dsDNA was immobilized at the surface of PGEs, then, the biointeraction was done in the presence of GLY. Electrochemical monitoring of the biointeraction was performed using differential pulse voltammetry (DPV) technique. The oxidation signal of guanine base was monitored at +1.0V and the changes at the guanine signal were evaluated in terms of the biointeraction process. Electrochemical monitoring of the biointeraction between dsDNA and GLY containing pesticide was also studied. The biointeraction was investigated using 25-150 µg/mL GLY or 5-25 µg/mL GLY contained pesticide during different exposure time varying from 5 to 30 min. The most decrease at the guanine signal was obtained in the presence of 100 µg/mL GLY or 15 µg/mL GLY contained pesticide during 5 min interaction. The results suggested that GLY caused DNA damage and GLY contained pesticide had more adverse effect on dsDNA structure. These results were in parallel to the results obtained by animal experiments or single cell gel electrophoresis (SGCE) assay. This is the first study in the literature for the electrochemical investigation of dsDNA and GLY interaction by using disposable PGEs.en_US
dc.identifier.urihttps://hdl.handle.net/11552/2501
dc.institutionauthorÇongur, Gülşah
dc.language.isoen
dc.publisherIOCENSen_US
dc.relation.ispartofInternational Online Conferences On Engineering And Natural Sciences
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDNAen_US
dc.subjectElectrochemical Biosensoren_US
dc.subjectGlyphosateen_US
dc.subjectPesticide-DNA Interactionen_US
dc.subjectPencil Graphite Electrodeen_US
dc.titleElectrochemical Monitoring of Biointeraction Between Glyphosate and DNA By Using Disposable Pencil Graphite Electrodes
dc.typeConference Object

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Abstract-Gülşah ÇONGUR-revised.pdf
Boyut:
53.2 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Yayıncı Kopyası_Özet Bildiri

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: