Effect of Aging Procedures on Phase Transformation of Posterior 3-Unit Zirconia Frameworks Used in Fixed Partial Dentures
| dc.contributor.author | Bulbul, M. | |
| dc.contributor.author | Palta, N. | |
| dc.contributor.author | Erdinc, G. | |
| dc.date.accessioned | 2025-05-20T18:53:34Z | |
| dc.date.issued | 2025 | |
| dc.department | Bilecik Şeyh Edebali Üniversitesi | |
| dc.description.abstract | Background: Zirconia is an essential material for dentistry, and its properties should be investigated in all aspects. Aim: The primary objective of this study was to assess the impact of aging procedures on the phase transformation of posterior 3-unit zirconia frameworks used in fixed partial dentures. Setting and Designs: The study considered three aging procedures: Group T underwent thermocycling with 20,000 cycles between 5 degrees C and 55 degrees C for 30 seconds, Group M experienced mastication cycles with 500,000 cycles at 1.3 Hz and 49 N force, and Group T + M was subjected to consecutive thermocycling (20,000 cycles/5-55 degrees C/30 s) and mastication cycles (500,000 cycles/1.3 Hz/49 N). Methods: E ach group comprised 12 specimens from manufactured presintered zirconia blocks (inCoris ZI, Sirona, Salzburg, Austria). The evaluation of phase transformation was performed through X-ray diffraction (XRD) analysis. Statistical Analysis: The obtained data were subjected to statistical analysis using one-way ANOVA and the Tukey tests (alpha = 0.05). Results: The study revealed statistically significant differences in the effects of aging processes on phase transformation in zirconia frameworks (P < 0.05). Group T + M demonstrated the highest phase transformation compared to other groups (P < 0.05). Moreover, significant differences were observed between the distal connector and pontic regions (P < 0.05). Conclusion: ll aging processes applied to zirconia increased the amount of monoclinic phase. | |
| dc.description.sponsorship | Scientific and Technological Research Council of Turkey (TUBIdot;TAK) [113S675] | |
| dc.description.sponsorship | The authors would like to acknowledge financial support from the Scientific and Technological Research Council of Turkey (TUB & Idot;TAK, Grant # 113S675). | |
| dc.identifier.doi | 10.4103/njcp.njcp_579_23 | |
| dc.identifier.endpage | 194 | |
| dc.identifier.issn | 1119-3077 | |
| dc.identifier.issn | 2229-7731 | |
| dc.identifier.issue | 2 | |
| dc.identifier.pmid | 40326900 | |
| dc.identifier.scopus | 2-s2.0-105001722350 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 188 | |
| dc.identifier.uri | https://doi.org/10.4103/njcp.njcp_579_23 | |
| dc.identifier.uri | https://hdl.handle.net/11552/6899 | |
| dc.identifier.volume | 28 | |
| dc.identifier.wos | WOS:001454314800018 | |
| dc.identifier.wosquality | Q3 | |
| dc.indekslendigikaynak | WoS | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.indekslendigikaynak | WoS - Science Citation Index Expanded | |
| dc.language.iso | en | |
| dc.publisher | Wolters Kluwer Medknow Publications | |
| dc.relation.ispartof | Nigerian Journal of Clinical Practice | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20250518 | |
| dc.subject | Aging | |
| dc.subject | phase transformation | |
| dc.subject | XRD | |
| dc.subject | Y-TZP | |
| dc.subject | Zirconia | |
| dc.title | Effect of Aging Procedures on Phase Transformation of Posterior 3-Unit Zirconia Frameworks Used in Fixed Partial Dentures | |
| dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1












