REDUCING DEAERATOR-RELATED ENERGY LOSSES IN STEAM BOILERS

dc.authorid0000-0001-8376-9234
dc.contributor.authorSavas, Ahmet Fevzi
dc.contributor.authorKocabas, Ceyda
dc.date.accessioned2025-05-20T18:54:07Z
dc.date.issued2023
dc.departmentBilecik Şeyh Edebali Üniversitesi
dc.description.abstractImproving energy efficiency helps to achieve a more reliable energy supply and a sustainable environment. In the current study, some observations were made in a textile factory to improve the energy efficiency of the industrial steam boiler. Deaerator is one of the main points of energy loss in the boiler. It is possible to reduce energy loss in the deaerator by using today's scientific and technological possibilities. The failure mode and effects analysis method was used in determining and ranking the factors causing energy loss in the deaerator. Some improvements were suggested based on the data of the failure mode and effects analysis study. The amount of energy loss in the deaerator was calculated by establishing mass and energy balances both in the current situation and after the improvements. As a result, when suggestions were applied, the energy loss in the deaerator, which was 373.6 kW before, could be reduced to 40.4 kW. Also, the net steam production capacity of the steam system will increase by approximately 9%. The pay-back period of the proposed investments was calculated as 2.8 months by performing the economic analysis. The study outcomes revealed that the failure mode and effects analysis technique, which is used as a risk analysis and failure prevention method within the scope of process improvement studies, can also be used to increase boiler energy efficiency.
dc.description.sponsorshipScientific Research Projects (BAP) Commission of Bilecik Seyh Edebali University [2019-01, BSEU.07-01]
dc.description.sponsorshipThis work was supported by the Scientific Research Projects (BAP) Commission of Bilecik Seyh Edebali University (Project No. 2019-01. BSEU.07-01, 2019) . https://bapoto.bi-lecik.edu.tr/index.php?act=guest&act2=projeler&durum=tamam
dc.identifier.doi10.2298/TSCI220616128S
dc.identifier.endpage1324
dc.identifier.issn0354-9836
dc.identifier.issn2334-7163
dc.identifier.issue2A
dc.identifier.scopus2-s2.0-85151778987
dc.identifier.scopusqualityQ3
dc.identifier.startpage1313
dc.identifier.urihttps://doi.org/10.2298/TSCI220616128S
dc.identifier.urihttps://hdl.handle.net/11552/7209
dc.identifier.volume27
dc.identifier.wosWOS:000959904600046
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWoS
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWoS - Science Citation Index Expanded
dc.language.isoen
dc.publisherVinca Inst Nuclear Sci
dc.relation.ispartofThermal Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250518
dc.subjectsteam boiler
dc.subjectdeaerator
dc.subjectenergy loss
dc.subjectenergy efficiency
dc.titleREDUCING DEAERATOR-RELATED ENERGY LOSSES IN STEAM BOILERS