Designing an electrochemical biosensor based on tyrosinase for highly sensitive and rapid detection of bisphenol A and its derivatives

dc.authorid0000-0001-9365-334X
dc.contributor.authorBodur, Onur Can
dc.contributor.authorKeskin, Merve
dc.contributor.authorAvan, Basak Arslan
dc.contributor.authorArslan, Halit
dc.date.accessioned2025-05-20T18:54:07Z
dc.date.issued2023
dc.departmentBilecik Şeyh Edebali Üniversitesi
dc.description.abstractBisphenol A (BPA) is a monomer commonly used in the production of epoxy resins, plastic bottles and dental filling materials. Due to its chemical structure, BPA and its derivates show activity similar to the endocrine hormones. It can bind to estrogen receptors and cause neurological disturbances, even at low doses. Therefore, it is important to determine BPA and its derivatives quickly and sensitively at low concentrations. In this study, a single amperometric tyrosinase enzyme biosensor was designed for the determination of the amount of BPA, bisphenol F (BPF) and bisphenol S (BPS) monomers. Tyrosinase was immobilized onto a modified carbon paste electrode by cross-linking with glutaraldehyde. The amount of BPA (BPS and BPF) was determined directly on the reduction of quinone compound released as a result of the enzymatic reaction at -0.15V. K-m( app) value of the designed biosensor for BPA was found 0.00067 mu M, the linear operating range was 0.001-0.005 mu M (a) and 0.03-0.1 mu M (b) and the lower detection limit was found 1 nM for each monomer. It is clear that designed biosensor enable the fast, efficient and precise determination of BPA and its derivatives released from materials used in dental materials.
dc.description.sponsorshipGazi University [05/2020-11]
dc.description.sponsorshipThis study was supported by Gazi University with project number 05/2020-11.
dc.identifier.doi10.2298/JSC221122013B
dc.identifier.endpage536
dc.identifier.issn0352-5139
dc.identifier.issue5
dc.identifier.scopus2-s2.0-85162220769
dc.identifier.scopusqualityQ3
dc.identifier.startpage521
dc.identifier.urihttps://doi.org/10.2298/JSC221122013B
dc.identifier.urihttps://hdl.handle.net/11552/7215
dc.identifier.volume88
dc.identifier.wosWOS:000994986500001
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWoS
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWoS - Science Citation Index Expanded
dc.language.isoen
dc.publisherSerbian Chemical Soc
dc.relation.ispartofJournal of The Serbian Chemical Society
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250518
dc.subjectBPA
dc.subjectBPF
dc.subjectBPS
dc.subjecttyrosinase enzyme
dc.subjectbiosensor
dc.subjectestrogen
dc.titleDesigning an electrochemical biosensor based on tyrosinase for highly sensitive and rapid detection of bisphenol A and its derivatives
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale.pdf
Boyut:
2.2 MB
Biçim:
Adobe Portable Document Format