Modified thermo-ecological optimization for refrigeration systems and an application for irreversible four-temperature-level absorption refrigerator

dc.authorid0000-0001-5356-1467
dc.contributor.authorAcikkalp, Emin
dc.date.accessioned2025-05-20T18:56:02Z
dc.date.issued2013
dc.departmentBilecik Şeyh Edebali Üniversitesi
dc.description.abstractIn this study, a modified ecological function is presented for four-temperature-level absorption refrigerators, and an absorption refrigerator has been optimized using this function. An equivalent system was initially identified, followed by the application of the first and second laws of thermodynamics. Next, the optimization results were interpreted. The results of the optimization process, optimum point of x(H), x(R), a(H), and a(R), were defined as 0.87, 0.58, 2.41, 0.25, respectively. In addition to that, the effects of x(H), x(R), a(H), a(R), T-a, T-c, Te, and Tg were shown according to exergy destruction, ecological function, coefficient of performance, and cooling load. As a result, it was understood that especially the x(H), parameter, and the generator temperatures are the variables of the system that require special attention because, at some points, they cause that generator and absorber transfer heat in the opposite direction they need to do.
dc.identifier.doi10.1186/2251-6832-4-20
dc.identifier.issn2008-9163
dc.identifier.issn2251-6832
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84881227566
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1186/2251-6832-4-20
dc.identifier.urihttps://hdl.handle.net/11552/7508
dc.identifier.volume4
dc.identifier.wosWOS:000219183400020
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWoS
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWoS - Emerging Sources Citation Index
dc.institutionauthorAcikkalp, Emin
dc.language.isoen
dc.publisherSpringer Heidelberg
dc.relation.ispartofInternational Journal of Energy and Environmental Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250518
dc.subjectAbsorption System
dc.subjectOptimization
dc.subjectIrreversibility
dc.subjectRefrigeration
dc.subjectEcological
dc.titleModified thermo-ecological optimization for refrigeration systems and an application for irreversible four-temperature-level absorption refrigerator